§ 38-1454. Vibration.  


Latest version.
  • (a)

    No operation or use in any of the industrial districts shall, at any time, create earthborne vibrations which, when measured at the bounding property line of the source of operation, exceed the limits set forth in the following tables:

    MAXIMUM PERMITTED VIBRATION IN THE C-3 COMMERCIAL DISTRICT, OR THE I-1, I-2 OR I-3 DISTRICT

    Frequency in Cycles
       per Second
    Acceleration G's Single Amplitude
        1 .00062
        2 to 5 .00084
        5 to 10 .00055
       10 to 20 .0014 
        20 to 50 .004  
       Over 50 .0092 

     

    MAXIMUM PERMITTED VIBRATION IN I-4 OR I-5 DISTRICT

    Frequency in Cycles
       per Second
    Acceleration G's Single Amplitude
        1 .016
        2 to 5 .02 
        5 to 10 .012
       10 to 20 .015
        20 to 50 .026
       Over 50 .046

     

    (b)

    Vibration shall be measured by normal vibration analysis equipment with associated transducer mounted vertically on two-inch pipe driven into the ground at least three (3) feet.

(P & Z Res., art. XVIII, § 4)